Example:
Set the target torque to 100.0: Target +
Press this target button ONCE to see the current target torque value.
Press and HOLD to INCREASE the target torque value.
Set the target zone to 4%: Hold and Press to change Go/No Go zone from 1-10% (or OFF)
Result:
When torque reading is just under 96.00 (4% of 100) the yellow light will come on prompting you to slow down.
When torque reading is above 96 and below 104 (± 4% zone) the green light* will come on.
When torque reading is above 104 the red light* will come on.
(* Note: Buzzer will sound when in Track or Peak mode.)
1
Unscrew the back cover, and you
will see the battery in the housing.
2
Unplug the battery and replace with a
new one.
3
Fit the wires connected to the battery
into the slot and screw the cover.
Rotating Display
359° rotary display for the conve-
nience of viewing.
External Alarm
Use DB9 connector for connection. Special
LED output version available. Contact factory.
Copyright 2006 Futek Advanced Sensor Technology, Inc.
DOC. No. MKTSFTAT12012006
www.futek.com Tel: 1-800-23-FUTEK or 949-465-0900 [email protected]
DISPLAY
PRIMARY KEY FUNCTIONS
Power - Press and HOLD button to turn ON or OFF (will AUTO
OFF after 5 minutes)
- Press during operation to CLEAR torque from display (in
PEAK HOLD MODE).
Target +
- Press target button ONCE to see current target torque value.
- Press and HOLD to INCREASE target torque value.
Target -
- Press target button ONCE to see current target torque value.
- Press and HOLD to DECREASE the target torque value.
Mode
- Press button to toggle between TRACK and PEAK
HOLD MODE. (PH will show on LCD when in PEAK
HOLD MODE.)
CCW Counter Clockwise Torque
SECONDARY KEY FUNCTIONS
Units HOLD And
Press
To change the UNITS
Target
Zone
HOLD
And
Press
To change Go/No Go
zone from 1-10% (or
OFF)
LCD
Contrast
HOLD
And
HOLD
To adjust LCD con-
trast (viewing angle)
Target Zone: Programmable Go/No Go zone (1-10% of target torque)
Lights: Yellow (just under target zone), Green (within target zone),
Red (over target zone)
Buzzer: Continuous when within target zone, intermittent when over
target zone.
Zero/Tare:
PRESS THE ZERO TARE BUTTONS IF THERE IS A
READING IN TRACK MODE WITH NO TORQUE APPLIED.
* If the wrench will not zero, while in track mode, a greater than 2.5% shift has
occured in the transducer, return for repair or recalibration.
FEATURES
SYMBOLS
1 Direction Indicator When arrow is illuminated under the CCW, the wrench is being used in the Counter Clockwise direction.
2 Unit Indicator When arrow is illuminated under the In-Lb, the meter is displaying In-Lb.
3 Battery ‘Low’ Indicator When ‘BATT’ is illuminated, the battery is low. Replace the 9 V battery as soon as possible.
4 Target Zone Indicator When the ‘%’ is illuminated, the Target Range can be set.
7 First Peak Allows only First initial Peak to be detected.
BATTERY
1
2
3
4
5
7
5 Peak Hold Indicator When the ‘PH’ is illuminated, the display is in the Peak Hold Mode (otherwise the display is in the Tracking mode).
6 Target Value Indicator When the target is illuminated, the user can set the target value.
6
TAT550/TAT560 QUICK START
Vue de la page 1
1 2

Commentaires sur ces manuels

Pas de commentaire